    On the usability of `compensated temperature` output of Honeywell PPTR sensor for coastal oceanographic and limnological studies

    Thumbnail
    View/Open
    Oceans_08_MTS_IEEE_Mehra_P.pdf (641.8Kb)
    Date
    2008
    Author
    Mehra, P.
    Joseph, A.
    Desai, R.G.P.
    Vijaykumar, K.
    Sundar, D.
    Tengali, S.
    Metadata
    Show full item record
    Abstract
    Usability of the temperature output, primarily meant for temperature-compensation of the pressure output of Honeywell silicon piezoresistive precision pressure transducer (PPTR) for sea-level measurements, is presented. Laboratory calibration in the range 2-50 degrees C against a platinum resistance thermometer showed linear response (typical example : y = 1.02x - 0.40 with R sup(2) = 1). It was found that beyond 15 degrees C, linearity and accuracy are better than 2% and plus or minus 1.5% respectively of the sensor's temperature output. However, the sensor's performance degrades below 15 degrees C. Field inter-comparison measurements from an offshore platform over a period of 36 days (3456 samples) between the temperature outputs of the PPTR and those of Aanderraa current meter's Fenwall GB 32JM19 thermistor probe and NIO water level recorder's YSI thermistor probes were encouraging. However, while the Fenwall GB 32JM19 thermistor probe and the YSI thermistor probes detects changes in temperature with fine resolution, the PPTR's observed temperature resolution is 0.1 degrees C only. As precautionary measures are undertaken as a technical requirement to prevent corrosion and bio-fouling effects at the water inlet of the sensor, the PPTR could be a useful tool for acquisition of long-term temperature measurements with a resolution of 0.1 degrees C, for limited applications at least, from tropical regions where the temperature is in a range in which the sensor has a linear response.
    URI
    http://drs.nio.org/drs/handle/2264/1068
    Collections
    • Scholarly literature [9074]

    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV